Steel Columns - "Extend-O-Steel Columns" - 3" DIA. ROUND & 3 1/2" DIA. ROUND (Adjustable Length)
Steel Columns - "Extend-O-Steel Columns" - 4" DIA. ROUND & 3" I.D. ROUND (Adjustable Length)
Steel Columns - 3" DIA. ROUND & 3 1/2" DIA. ROUND (Fixed Length)
Steel Columns - 4" DIA. ROUND & 3" I.D. ROUND (Fixed Length)

Accessories
ICC-ES Legacy Rpt. 94-54

Steel Columns

Fixed Length

Steel Column - 4" Diameter  Fixed Length

Steel Column - 4" Diameter
4" Diameter Round - 11 Gauge
Meets FHA Specifications - ICC-ES Legacy Report 94-54
Model
Length
Weight
Maximum Load*
FC459
5'9"
32.75#
23,000#
FC460
6'0"
34.00
22,850
FC463
6'3"
35.25
22,650
FC466
6'6"
36.50
22,500
FC469
6'9"
37.75
22,300
FC470
7'0"
39.00
22,100
FC473
7'3"
40.25
21,950
FC476
7'6"
41.50
21,750
FC479
7'9"
42.75
21,550
FC480
8'0"
44.00
21,300
FC483
8'3"
45.25
21,100
FC486
8'6"
46.50
20,850
FC489
8'9"
47.75
20,650
FC490
9'0"
49.00
20,400
FC493
9'3"
50.25
20,150
FC496
9'6"
51.50
19,900
FC499
9'9"
52.75
19,650
FC410
10'0"
54.00
19,350

• 2 "B" plates furnished with each column. Specify loose, or one welded and one wired.
• Flow-coated inside and out with red corrosion-resistant paint.
• Special sizes available on request.
• Standard Bundles:
4" - 25 pcs.
3 Sch. 40" - 25 pcs.

Steel Column - 3" ID Fixed Length

Steel Column - 3" ID
3" Inside Diameter Round - Sch. 40
Meets FHA Specifications - ICC-ES Legacy Report 94-54
Model
Length
Weight
Maximum Load*
AC3P59
5'9"
47.7#
38,950#
AC3P60
6'0"
49.6
38,550
AC3P63
6'3"
51.5
38,150
AC3P66
6'6"
53.4
37,700
AC3P69
6'9"
55.3
37,250
AC3P70
7'0"
57.2
36,800
AC3P73
7'3"
59.1
36,300
AC3P76
7'6"
61.0
35,850
AC3P79
7'9"
62.9
35,300
AC3P80
8'0"
64.8
34,800
AC3P83
8'3"
66.7
34,250
AC3P86
8'6"
68.6
33,700
AC3P89
8'9"
70.5
33,100
AC3P90
9'0"
72.4
32,500
AC3P93
9'3"
74.3
31,900
AC3P96
9'6"
76.2
31,250
AC3P99
9'9"
78.1
30,600
AC3P10
10'0"
80.0
29,950
IMPORTANT
Column selection should be based upon structural calculations completed by a registered professional engineer. Not responsible for the installation, alteration, or modification of any completed product, or the usage of any component in the fabrication of any product beyond our control. See ICC-ES Legacy Report 94-54.