MARSHALL
STAMPING COMPANY
Manufacturer of
Quality Building Products
Since 1951
355 Glade Mills Rd. • Valencia, PA 16059-3315 • Phone: 800-635-1166 • Fax: 724-898-3339 • info@marshallstamping.com

Access Doors, Foundation

Anchor Bolts

Angles, Rolled

Area Walls & Accessories

Ash Dumps

Bar Strainers (C.I.)


Basement Windows

Baskets, Fireplace

Bell Traps (C.I. & PVC)

Brick Clamps

Chimney Caps

Cleanout Doors (C.I. & STL)

Columns


Dampers/Controls (C.I.)

Foundation Anchors

Jack Posts

Lintels, Block & Brick

Mortar Boxes & Pans

Nail Stakes (Steel)

Rebar Caps

Rebar Chairs

Tie Wire

Trench Drain

Ventilators, Brick and FND.

Wall Ties

sep

pdf

Extend-O-Columns - 3"  ,  3 1/2" &  4" Dia. 11Ga. ,  3 1/2" Dia. .216 Wall
Fixed Length Columns - 3" ,  3 1/2" &  4" Dia. 11Ga. ,  3" Dia. .216 Wall

Column Accessories
ATI-ES Code Compliance Research Report (CCRR-0145)

Columns

Adjustable Length - "Extend-O Columns"

Print Friendly Link


Steel Column - 3" Diameter 11 Gauge
Column - 3" Diameter

• Complies with IRC + IBC

• Completely Assembled:

  4" x 8" plate welded to top end and 3 1/2" x 6" Plate permanently attached to screw on bottom end.

• Flow-coated inside and out with red corrosion-resistant paint.

• Straps availiable on request.

• Standard Bundles: 3" - 40 pcs.

3" Diameter Round - 11 Gauge
See ATI-ES Code Compliance Research Report CCRR-0145
Model
Adjustable Length
Weight
Maximum Load*
AC360
6'0" to 6'4"
29#
18,700
AC363
6'3" to 6'7"
30
18,200
AC366
6'6" to 6'10"
31
17,800
AC369
6'9" to 7'1"
32
17,300
AC370
7'0" to 7'4"
33
16,800
AC373
7'3" to 7'7"
34
16,300
AC376
7'6" to 7'10"
35
15,800
AC379
7'9" to 8'1"
36
15,300
AC380
8'0" to 8'4"
37
14,800
AC383
8'3" to 8'7"
38
14,200
AC386
8'6" to 8'10"
39
13,800
AC389
8'9" to 9'1"
40
13,300
AC390
9'0" to 9'4"
41
12,800
AC393
9'3" to 9'7"
42
12,300
AC396
9'6" to 9'10"
43
11,800
AC399
9'9" to 10'1"
44
11,300
AC3100
10'0" to 10'4"
45
10,900
AC3103
10'3" to 10''7"
46
10,400
AC3106
10'6" to 10'10"
47
10,100
AC3109
10'9" to 11'1"
48
9,500
AC3110
11'0" to 11'4"
49
9,100
AC3113
11'3" to 11''7"
50
8,700
AC3116
11'6" to 11'10"
51
8,300
AC3119
11'9" to 12'1"
52
8,000
AC3120
12'0" to 12'4"
53
7,600
All loads listed are with the adjustable screw extended 6 1/2", and encased in concrete.

 


IMPORTANT
Column selection should be based upon structural calculations completed by a registered professional engineer. Not responsible for the installation, alteration, or modification of any completed product, or the usage of any component in the fabrication of any product beyond our control. See ATI-ES Code Compliance Research Report (CCRR-0145).